text.skipToContent text.skipToNavigation

回路模块密封件

1406-3463-000
全新
麻醉设备
Aestiva
GE医疗
GE HealthCare
不需归还
加入愿望清单
登录并添加到购物车
登录并添加到购物车
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


备件描述

The Seal Bain Module Cover BCG B/S Mechanical is used in Bain model assembly in Breathing Circuit Gas Module which comes under the modality of Anesthesia Delivery. This Bain module circuit is having the fresh gas supply tube runs coaxially inside the corrugated tubing. The diameter of the outer tubing is 22 mm and inner tubes is 7 mm. Length of the circuit is 1.8 meters. Outer tube is transparent so that inner tube can be seen for any disconnection or kinking. Length of the circuit can be increased to modify it for use at remote locations. Various studies have been done to analyze its efficiency after increasing its length. It is seen that as the length increases, the resistance increases during spontaneous breathing. Also, ventilator settings should be adjusted to deliver set tidal volume with long Bain's circuit as there is reduction in the peak inspiratory pressure and tidal volume with increased length of the circuit. The patient inspires fresh gas from the circuit, and excess gases are vented out through the APL valve during expiration. In controlled ventilation the APL valve is kept partially closed and patient is ventilated by squeezing the reservoir bag. Here excess gases are vented out during inspiration. This part is widely used in Aestiva 7900, Aestiva 7100 and Aestiva MRI. The part is diligently designed for superior performance and reliability. It is securely packed inside a high quality packing box to avoid physical damage during transit and labeled with details about the product, Quality Assurance (QA) seal and shipment details.

适配的产品

Aestiva

Aestiva

Aestiva 7900

Aestiva 7900